Generator Set Equipment

Our generator set equipment is mainly built with imported VOLVO diesel engines, paired with LOREY SOMER (France) or FARADAY AC alternators and BFK control systems. These generator sets are widely used in oilfield power systems, with features including low fuel consumption, low noise, minimal vibration, compact design, small footprint and easy mobility.
The exhaust system of our generator sets meets European environmental standards. Operation is simplified by the backpack-style electric control panel and built-in integrated circuit. The unit includes full protection and alarm systems for high water temperature, low oil pressure, overspeed, overcurrent and circuit fault, and supports automatic remote control and automatic parallel operation.
We offer 15 standard generator set configurations: 56, 68, 80, 104, 121, 149, 165, 200, 260, 300, 327, 370, 400, 456 and 500 kW.
Optional equipment: automatic ATS transfer switch and parallel operation control cabinet.

Features

As a generator set equipment supplier, our company has introduced the TTI generator simulated load testing device from TOMSIN Company of Canada. Every generator set has passed strict simulated load testing before leaving our factory.

Typical Applications

Our diesel generator sets are used as reliable standalone power sources for drilling rigs, remote field camps, and isolated oilfield sites with no access to the centralized grid.

- Core use cases: primary or backup power for drilling rigs, power supply for remote well pads, field staff camps, and operational bases, as well as powering drilling mud pumps and control systems for remote field operations.
- Typical customers: drilling contractors and remote field operators in Siberia, Central Asia and Africa, where the nearest grid connection is dozens of kilometers away, making permanent power line construction economically unviable.
- We supply generator sets across a wide power range from 100 kW to 2000 kW, so we can match the exact power requirement of your site.

Rigorous Factory Testing Before Shipment

Our in-house TTI test rig, sourced from TOMSIN of Canada, lets us run full simulated load testing on every generator set right at our factory. Each unit runs for hours at full rated load before dispatch, eliminating the risk of delivering equipment with hidden factory defects.

- During testing we verify all operating parameters: output voltage, frequency, engine and alternator temperature, fuel consumption, vibration and noise level.
- We provide a full factory test report with every unit, listing all measured parameters, so you can be confident the equipment is ready to operate on arrival.
- Our generator sets are fitted with globally recognized diesel engines (Cummins, Perkins, Weichai), proven for reliable performance in harsh field conditions.

Autonomous Operation for Remote Sites

All our generator sets come with integrated base fuel tanks that support 8–12 hours of continuous operation without refueling. We can also supply large external auxiliary fuel tanks on request, enabling weeks of continuous operation without refueling stops.

- Every unit comes with automatic control systems that hold output voltage stable to within ±1% even as load changes.
- Units can be supplied in weatherproof container enclosures on request, rated for operation in temperatures from -50°C to +50°C, fully protected from the elements.
- All units include full safety alarm and shutdown systems that stop the engine on low oil pressure, overheating, or other faults to prevent equipment damage.

Frequently Asked Questions

Q: What power range of generator sets do you supply?
A: We supply units from 100 kW to 2000 kW. Multiple units can also be paralleled together to support larger site loads.

Q: Can generator sets be paralleled with the main grid?
A: Yes, we can equip units with synchronization systems to parallel multiple generators together, or sync them to an external utility grid connection.

Q: What is your lead time for generator sets?
A: Standard units up to 500 kW are kept in stock and ship within 1 week. Higher-capacity units are built to order with a 4–6 week lead time.

Maintenance Recommendations

For reliable long-term operation of your diesel generator set, we recommend:

- Follow the manufacturer-scheduled maintenance intervals for the engine, and replace engine oil and filters on time.

Parameters

Type Frequency 50Hz Diesel Engine Type Motor model Cant./Type de cilindro Cylinder Bore × Stroke (mm) Descarga de aire (L) Tasa de consumo de combustible con carga al 100% (g/kW·h) Capacidad de aceite lubricante (L) Overall Dimensions (L×W×H) Peso (kg)
Potencia de reserva Potencia principal VOLVO STAMFORD
SVL70 60 56 TD520GE UCI224F 4.L 108X130 4.76 208 13 1938X866X1409 1230
SVL85 75 68 TD520GE UCI224G 4.L 108X130 4.76 208 13 1983X866X1409 1260
SVL100 87 80 TAD531GE UCI274C 4.L 108X130 4.76 206 13 2127X866X1400 1310
SVL130 114 104 TAD532GE UCI274E 6.L 108X130 7.15 206 20 2351X866X1400 1321
SVL152 133 121 TAD731GE UCI274F 6.L 108X130 7.15 203 20 2393X866X1400 1640
SVL186 165 149 TAD732GE UCI274H 6.L 108X130 7.15 203 34 2469X1003X1514 1750
SVL205 181 165 TAD733GE UCI274H 6.L 108X130 7.15 203 34 2556X1003X1491 1750
SVL250 222 200 TAD734GE UCDI274K 6.L 108X130 7.15 203 33 2804X1050X1591 2020
SVL325 286 260 TAD941GE HCI444E 6.L 120X138 9.36 203 33 2944X1120X1591 2418
SVL375 329 300 TAD1241GE HCI444F 6.L 131X150 12.13 198 35 3078X1120X1587 2837
SVL408 360 327 TAD1242GE HCI444F 6.L 131X150 12.13 198 35 3078X1120X1587 2837
SVL462 405 370 TAD1640GE HCI544C 6.L 144X165 16.12 198 48 3329X1160X1881 3411
SVL505 440 400 TAD1641GE HCI544D 6.L 144X165 16.12 198 42 3329X1160X1881 3476
SVL570 505 456 TAD1642GE HCI544E 6.L 144X165 16.12 198 48 3329X1160X1881 3556
SVL625 550 500 TWD1643GE HCI544FS 6.L 144X165 16.12 198 48 3419X1350X1930 4200